POWER RATING
|
500 VA
|
Voltage
|
160 – 270 V AC
|
Frequency
|
47 – 53 Hz
|
Phase
|
Single Phase
|
Battery
|
12V, 7AH, SMF (Internal)
|
OUTPUT
|
|
Voltage on Mains
|
220V + 20 V AC (Nominal)
|
Voltage on Battery
|
220V + 20 V AC (RMS)
|
Regulation
|
+ 2% for 10 to 90% load change.
|
Frequency
|
50 Hz + 1%
|
Wave form
|
PWM Stepped Sine Wave.
|
AVR Correction Time
|
Less than 10 m. seconds for given Input Range.
|
TRANSFER
|
|
Time
|
Less than 3 m. seconds.
|
Mains to Inverter
|
Low voltage at 160 V and High voltage at 270 V.
|
Inverter to Mains
|
Low voltage at 165 V and High voltage at 265 V.
|
Recharge Time
|
4 hours to 6 hours.
|
Load
|
1 PC + 1 Printer (not Laser Printer).
|
Back Up
|
15 Minutes.
|
PROTECTIONS
|
|
Input
|
Fuse.
|
Output Over Load
|
Electronic Protection in Backup Mode, if Load exceeds 110% of Rated Capacity.
|
Output
|
Fuse
|
Spike
|
Surge and Spike Suppression.
|
INDICATIONS (LED’s)
|
|
Mains OK (Green)
|
When Mains Voltage is within Input Range.
|
Back Up (Yellow)
|
Blinks every 10 seconds in Inverter Mode and every 1 second for Battery Low alarm.
|
Power Save (Yellow)
|
UPS trips after 30 seconds, if Load is <5% of Rated Capacity. Manual Reset.
|
Over Load (Red)
|
UPS trips due to excess Load (more than 110% of rated capacity) or due to Output Short.
|
Battery Low Trip (Red)
|
UPS shuts down due to Low Battery Voltage.
|
ALARM
|
|
Mains Failure
|
Beeps every 10 seconds for Line Failure.
|
Battery Low
|
Beeps every 1 second, after 75% of battery discharge till UPS trips Off due to Low Battery.
|
Interface (Optional)
9 Pin, ‘ D’ Connector
|
Provides AC Failure, Battery Low and Shut Down Signal for manual Shut Down. Can support single PC or Server under NOVEL, NetWare, UNIX, MS-DOS, MS-WINDOWS. Special Interface Cords and associated software are available.
|
Physical Dimensions
|
110 x 335 x 185 mm (W x D x H)
|
Weight
|
9.5 Kg (Including Internal Battery)
|
Output Receptacles
|
6 Amps - 3 Nos.
|